BNK and gateways
Many sites, one platform
What decides the site and the tier in an AI Grid, and how power becomes an input with DSX
One name, three factories ended with DNS choosing a site on residency, health, distance and spare capacity. That keeps a service up. Placing inference well takes more. A prompt that needs a small model belongs near the user. A long reasoning task belongs on a large factory. A coding agent on turn twelve belongs wherever its conversation is already held in GPU memory. NVIDIA's name for the answer is an AI Grid: many sites in many places that behave as one inference platform. This lesson follows what decides the site and the tier beyond plain GSLB. Then it follows NVIDIA DSX, where the power a site may draw becomes one more input to routing and scheduling.
Chapter 1 of 12
Many sites, one platform
What NVIDIA means by an AI Grid
One name, three factories showed three sites behind one name. NVIDIA's AI Grid reference design turns that picture into a general design. It defines an AI Grid as a set of geographically distributed, interconnected AI infrastructure sites that operate as one platform, with each workload placed where it runs best for performance, cost and latency. The sites are of very different sizes: a central AI factory, regional hubs, and edge nodes in telephone exchanges and content delivery buildings.
The design rests on four properties. Distributed means accelerated computing sits in many telco and content delivery sites, close to where data is produced and answers are used. Interconnected means a fast network with low latency links the sites, so data, models and workloads can move between them. Orchestrated means a control plane keeps weighing SLAs, latency, cost and policy, and routes each workload by what it is. Unified means one deployment model, so an application behaves the same in a central factory, a regional hub or an edge node.
The scale is what makes this more than a diagram. NVIDIA counts about 100,000 distributed network data centres worldwide, made up of regional hubs, mobile switching offices and central offices, with enough spare power for more than 100 gigawatts of new AI capacity over time. Northlight's three sites are the same idea in small. In this lesson Madrid is the small site, Amsterdam the middle one and Frankfurt the large factory.
Chapter 2 of 12
Three groups of problems
Capacity, placement and operations
The deck sorts what an AI Grid is for into three groups. The first is capacity. The buildings, power and network of those 100,000 sites already exist and sit idle or underused. A single factory also has a ceiling: it cannot grow past its grid interconnect, the connection to the electricity network that fixes how much power the site may draw. More capacity then has to come from more sites. For a telco, radio access network sites and central offices are points of presence it already owns and can earn from.
The second group is placement. Interactive inference, vision and speech cannot wait for a round trip to a distant factory. Serving everything the same way wastes hardware in both directions. A simple prompt answered on a GB300 rack is misplaced, and so is a reasoning task sent to an edge box. Regulated tenants add sovereignty and residency: their data, models and logs have to stay inside one jurisdiction.
The third group is operations. Sites differ in hardware, so deployment is inconsistent. Without one control plane, each site is run by hand on its own. Selling inference needs more than running it: hard multi-tenancy, which the reference design defines as strict isolation at hardware and software level, role-based access control, token metering, and a marketplace for AI as a service, where model APIs are sold as metered services. The deck sums it up as the right inference in the right places, and it still has to be good inference.
Chapter 3 of 12
Distance is part of the first token
Where inference runs sets two of five delays
Placement matters because distance is part of the answer time. NVIDIA's AI Grid blog takes voice as the example. Once a reply takes longer than about 500 milliseconds, a conversation feels laggy, so the time to first token at the client becomes a hard objective. That time is the sum of five parts: the network round trip, the wait in a queue before the GPU starts, tokenization, which for voice includes speech recognition and speech synthesis, prefill and decode in the model, and voice activity detection, which finds where a speaker starts and stops. The first two are set mostly by where inference runs.
NVIDIA published an operator's benchmark of this. The same small voice model ran on 4 RTX PRO 6000 GPUs in total in each of two layouts: one central cluster, and a grid spread over 4 sites. Both took a burst of sessions that arrive together. The grid kept end to end latency inside 500 milliseconds from normal load to burst. Its throughput rose to 42,362 tokens per second at burst, 80.9% above its own baseline, while the central cluster lost throughput. Cost per token was 52.8% lower on the grid at baseline and 76.1% lower at burst.
The blog gives the reason. A central cluster spends much of its latency budget on the round trip, so it has to run its GPUs at lower utilization to keep slow responses rare. A grid site keeps the round trip short and can drive its GPUs harder at the same target. NVIDIA adds that results vary with model, workload and network.
Chapter 4 of 12
A control plane that reads the work
Orchestrator, global load balancer, LLM router
The reference design puts a control plane over the sites and gives it three working parts. The AI Grid Orchestrator keeps the state: which clusters are healthy, where capacity is free, and which pods, clusters and models are deployed where. When a node's heartbeat stops, it provisions the model somewhere else. The global server load balancer handles incoming requests and decides where each is sent. It may keep a ranking list built from criteria the provider sets, it looks at hardware signals such as connection counts and CPU or GPU utilization, and it can take periodic updates from the Orchestrator. The LLM router reads the request itself: context, complexity and metadata, and directs it to the most suitable model. It may also answer a repeated question from a semantic cache. NVIDIA Dynamo, which has its own lesson, serves the model behind these.
The design lists what this control plane routes on that a plain load balancer does not. Prompt awareness: simple interactions go to lighter nodes and complex reasoning to dense GPU clusters. Resource and utilization awareness: no node becomes a hotspot. Multi-tenancy: the grid is sliced, with guaranteed performance for high priority tenants. Data governance: residency and sovereignty rules are enforced at request time. Security: access control, and routing decisions that can be audited. It also steers requests to instances likely to hold their KV cache.
One limit follows from the earlier lesson. DNS never sees the prompt. Anything prompt-aware has to be decided at a tier that terminates the request.
Chapter 5 of 12
The edge-terminated design
Tiers stacked the way a CDN stacks them
The deck draws two ways to arrange these decisions across sites. The first is stratified, or hierarchical, and follows the pattern of a content delivery network: the request terminates at the edge. At the top is the far edge, which holds devices only. Below it is a tiny factory at an edge or radio site, with RTX servers and air cooling. Then come small factories, also RTX and air cooled. At the bottom is the AI factory, with HGX systems and liquid cooling. The reference design's hardware fits these tiers: RTX PRO Servers in 2U and 4U for regional hubs and edge sites, in racks under 15 kW or under 25 kW, and HGX B300 systems at the centre.
Every tier makes its decisions locally. In this design GSLB uses proximity and health only. Its answer moves when a site's health changes, and the deck notes that its policy changes only through configuration. The border of the edge tier does factory routing on model, complexity, latency and security. The borders of the lower tiers decide on model and security. At every tier the gateway decides tenancy and availability, and inference follows the endpoint picker's policy.
The intelligence sits in the border at the edge, because that is the first place that can read the prompt. A request the tiny factory cannot serve is passed down to a larger tier. So a long reasoning task still enters at the edge and crosses the tiers above the factory before it reaches a GPU that can run it. In the scene Madrid plays the edge tier and Frankfurt the factory.
Chapter 6 of 12
The factory-terminated design
Peers of different size, and a GSLB that knows more
The second design is isotropic, or peered. Every site is a full factory, the sites are peers, and a request terminates at the factory that will serve it. The deck draws three peers of 50, 200 and 500 megawatts and notes that the tenant has the same models deployed in all regions. Here those are Madrid, Amsterdam and Frankfurt, 750 megawatts together. Since any site can run any request, the first choice carries more weight, and GSLB is given more to decide with.
Its inputs in this design are health, capacity, the tenant's SLA, the energy a site spends per token in millijoules, the locational marginal price and the carbon footprint. The locational marginal price is the wholesale price of electricity at one point of the grid at one time, and it differs between places and hours. Below GSLB the tiers decide what they decided before: the border on model, complexity, latency and security, the gateway on tenancy and availability, inference by endpoint picker policy. The deck's summary is intelligent routing at all regions and all tiers through BIG-IP programmability.
F5 has a product at each tier. CNF DNS Services is GSLB. The provider border is named for NICo load balancing and DPF in zero trust mode, on BlueField DPUs that NVIDIA Infra Controller and DPF manage, the subject of another lesson. BIG-IP Next for Kubernetes is the tenant gateway. F5 EPP picks the replica. F5 Terg supplies the energy measure. A tenant SLA needs DNS to know the tenant, and the deck's example name carries the tenant and the region as labels.
Chapter 7 of 12
An agent's next turn
Four tiers, and each one has to be right
Now take one caller: a coding agent that works for tenant acme. An agent resends the whole conversation on every turn. The model server keeps a KV cache, the stored intermediate results for tokens it has already read, in GPU memory. On turn 12 the prompt is 60,000 tokens, of which 58,500 were in turn 11 and 1,500 are new. A replica that still holds the prefix reads 1,500 tokens. Any other replica reads all 60,000, forty times the work, before the first token comes out.
The deck states the goal as a question of which copy of this conversation's cache is the closest, and adds that persistence is hard. Underneath one request it counts 3 regions, 9 AI factories, border gateways in each region, a tenant VRF, which is a private routing table for one tenant, several tenant gateway nodes per region and several inference GPUs per tenant. Four things have to be right. The turn should land in the region that served the last one. It should be delivered securely to the tenant's cluster, with the endpoint picker that already placed the conversation. It should arrive through a DPU that is still up and still serves that tenant's hosts. It should reach the replica that still holds the prefix.
The first tier is the hard one for DNS. An answer lives 30 seconds and turns are minutes apart. A GSLB ranking on price alone could answer Madrid for turn 12. So where the conversation already is has to rank above price and carbon for this request.
Chapter 8 of 12
Inside the region
Border, tenant gateway, picker, replica
Inside Frankfurt the other three tiers take over. The first is the provider's border, which is shared by all tenants. Its job is to deliver the request into the right tenant's cluster and nowhere else, and it does that through the tenant VRF. The deck names this tier for NICo and DPF. NICo, the NVIDIA Infra Controller, is an open source set of microservices for zero trust lifecycle management of bare metal, and DPF, the DOCA Platform Framework, deploys and operates services on BlueField DPUs.
The next tier belongs to one tenant: its gateway, BIG-IP Next for Kubernetes. A region holds several gateway nodes for a tenant. The turn has to come in through a DPU that is still up and still serves that tenant's hosts. If the DPU that carried turn 11 has failed, another node takes the connection, and it has to ask the same endpoint picker, because the picker is what remembers where the conversation was placed.
The last tier is inference. F5 EPP knows which replica read this prefix last and whether that replica has room. If the blocks are still in GPU memory, the request goes there and prefill covers 1,500 tokens. If they were evicted to make room for other work, the picker chooses by load and the full 60,000 tokens are read again. The picker's wiring is covered in its own lesson. The four tiers multiply. A turn that reaches the right region, the right cluster and the right gateway and then the wrong replica costs the same as one that went to Madrid.
Chapter 9 of 12
What DSX is for
A site's megawatts were treated as fixed. They are not
Every chapter so far treated a site's capacity as given. NVIDIA DSX is about where that capacity comes from. NVIDIA describes DSX as a platform of reference designs, APIs, software libraries and technologies to design, simulate, build and operate AI factories. The deck's one line is that DSX puts every layer of the factory under software control, from the reference design to the grid connection, with tokens per megawatt as the objective.
The deck lists four groups of problems behind it. Design: every operator worked out compute, fabric, power and cooling from scratch, which at gigawatt scale is an expensive mistake waiting to happen, and thermal and electrical errors were found after the concrete was poured. Power: static provisioning strands capacity, because sizing every rack for its nameplate peak, called MaxP, wastes the site's envelope. The power grid sees AI as a hostile load, and resistance to granting an interconnect delayed new builds.
Operations: IT and OT did not speak. OT, operational technology, is the building management system, cooling and power, and it lived apart from the software stack. Fleet work was done by hand: provisioning and tenancy, configuration drift and fault remediation were home grown and costly to keep. Multi-tenancy on bare metal was immature. Ecosystem: OT vendor products are very expensive, integrators who know real data centre automation are scarce, and NVIDIA's cloud partners want open parts they can adopt one at a time. Hyperscalers spent decades and millions on these problems.
Chapter 10 of 12
Design, simulate, deploy
The layers of DSX and what is in each
The deck lays DSX out in three layers. Design is a set of validated reference designs to rack a factory: GB300 NVL72, HGX B300 and Vera Rubin NVL72 systems, and rack classes under 15 kW, under 25 kW and over 25 kW. Simulate is NVIDIA Omniverse digital twins of the site before it is built: air cooling, water cooling, power distribution, the power grid interconnect, and the network, with a Clos fabric north-south and InfiniBand or Ultra Ethernet east-west. NVIDIA's public blueprint for this contains the geometry of a 50 acre reference site, a fluid dynamics simulation of hot aisles and an electrical loading simulation.
Deploy is software in five groups. Infrastructure and tenancy is NICo, which provisions bare metal and manages its lifecycle for many tenants. Runtime consistency is AICR, the AI Cluster Runtime, which generates validated, version-locked configuration for GPU Kubernetes clusters. Health and resiliency is NVSentinel, which detects GPU faults, cordons the node, drains it and starts repair without a person, together with Fleet Intelligence, which tracks inventory, integrity and health of the GPU fleet. Workload serving is Dynamo for inference, and Run:ai or NVIDIA Cloud Functions to share GPUs and scale workloads across clusters. Power and grid is MaxLPS with Dynamic Power Software, DSX Flex and DSX Exchange.
The deck's diagram stacks the same parts from the ground up: the facility, the racks, the DSX OS control layer, the tenant clusters, and on top Fleet Intelligence, NICo's API and the AI Grid control plane. That top line is where one site joins the grid.
Chapter 11 of 12
Power the software can move
MaxP, MaxQ, MaxLPS and a target from the grid
The power group is what turns megawatts into something software can move. NVIDIA's documents start with two static settings. MaxP is the highest GPU power setting, and rack and row power and cooling are designed for it. MaxQ is the setting with the best performance per watt. It caps the GPU below MaxP, and on its own it coordinates nothing across the factory. A Vera Rubin rack is allocated 227 kW at MaxP. That figure is a planning number, and observed draw sits below it most of the time, because tenants and workloads do not all peak together. The gap is stranded power.
DSX MaxLPS manages that gap inside a fixed site envelope. It has three parts: a facility designed for liquid cooling supplied at 45°C, which lowers cooling overhead where the climate allows, Dynamic Power Software, and techniques that raise performance per watt. DPS runs a loop every few seconds. It reads GPU and rack power telemetry, finds unused allocation, and sets a power limit for each GPU at the server's BMC, its management controller, over Redfish. Spikes of milliseconds are left to hardware and electrical protection. DPS manages power and leaves job placement to the scheduler. NVIDIA puts the gain at up to 40% more GPUs in the same envelope.
DSX Flex adds the grid. A grid-facing provider publishes a load target for a period, DSX Exchange carries it as an event, and DPS brings the managed GPUs under it. The site reports its state back as a stream of snapshots. A site that can do this is easier for a utility to approve and connect.
Chapter 12 of 12
Terg: energy per token, per tenant
What power policy lacks, and what routing gains
One thing is missing from that loop. DPS sees GPUs, racks and groups. A load target names kilowatts on a feed. Neither knows whose tokens a watt is producing. The deck says it directly: DSX has no way to base power changes on tenancy, and its tokens per megawatt objective is priced but never measured.
F5 Terg fills the gap. It joins three things into one measurable unit: energy in millijoules, tokens, and the state of the silicon. The result is millijoules per token, known per tenant. The unit converts cleanly. One megawatt is a billion millijoules each second, so tokens per second per megawatt is a billion divided by the millijoules per token. At 250 mJ per token a megawatt yields 4.0 million tokens per second, and at 400 mJ it yields 2.5 million. The deck adds that Terg sees processes bound to the host, which the GPU's own management view misses, and that it plugs into DSX Exchange natively over NATS and MQTT.
With that number, energy policy can know tenants, and power policy can include a tenant's SLA. Take a target that cuts a Frankfurt feed from 860 kW to 500 kW. A cut spread evenly slows acme's coding agents as much as a batch tenant. A tenant-aware cut takes the 360 kW from the batch tenant and leaves acme whole. The same number travels up to GSLB as a site's energy per token. New conversations then lean toward the site where a token costs least in energy, money and carbon, while turn 12 still goes back to its cache.
What to keep
Site, tier, replica, and the power under them
An AI Grid makes many sites behave as one inference platform, and that takes more than a DNS answer by distance and health. The site is chosen with the tenant, the model's location, energy price and carbon in view. The tier that reads the prompt, the border, decides what DNS cannot. For an agent's next turn the region, the tenant's cluster and its endpoint picker, and the replica all have to be the ones that served the last turn, and the gateway has to be one whose DPU is up and serves the tenant's hosts, or the cache is lost. Under all of it, DSX makes a site's power something software sets, and F5 Terg measures what that power yields in tokens for each tenant. Routing and power policy then work from the same number.